Dear friends:
       
      The mesh1 has 2*2 element , with an order of 40.
      The mesh 2 has 8*8 element, with an order 0f 10.

      I am  using these meshes with same order for the simulation of lid driven cavity problem at Re=1000. Both system can give converged solutions with a time step of 0.001.    But mesh1's results is different from the benchmark solution greatly. 
       Could you please give me some suggestions about this phenomeno.

Regards
   









At 2016-08-22 21:02:26, "Chris Cantwell" <c.cantwell@imperial.ac.uk> wrote: >Dear Ding, > >In what way does your measurement differ from the literature. Is the >difference substantial? Could you provide a plot of the output showing >the differences? > >One challenge in this problem is the inconsistent boundary conditions at >the ends of the top wall. The values used at the top left and top right >corners depends on the order of the boundary conditions. You could >therefore swap the order of the boundary regions/conditions in the XML >file and see if that improves your solution? > >Cheers, >Chris > > >On 22/08/16 06:15, ¶¡ÀÏʦ wrote: >> Dear Nektar group: >> I am conducting numerical simulation for 2D lid driven cavity >> problem with Re=1000. Attachment please find my xml file. >> But i found the output results at monitor point is different from >> benchmark solution from open literature. I have changed the order from >> 20 to 40, the nothing changed. >> but the stream line pattern is the same with benchmark solution. >> what should i do further> >> >> >> Regards >> Your Sincerely >> Ding >> >> >> >> >> >> >> >> >> >> >> >> >> >> >> _______________________________________________ >> Nektar-users mailing list >> Nektar-users@imperial.ac.uk >> https://mailman.ic.ac.uk/mailman/listinfo/nektar-users >> > >-- >Chris Cantwell >Imperial College London >South Kensington Campus >London SW7 2AZ >Email: c.cantwell@imperial.ac.uk >www.imperial.ac.uk/people/c.cantwell > >_______________________________________________ >Nektar-users mailing list >Nektar-users@imperial.ac.uk >https://mailman.ic.ac.uk/mailman/listinfo/nektar-users