Hi, I am not sure on that, but I do recall that the Lagrange
basis might be only implemented for quadrilateral in 2D and cuboid
(?) in 3D elements.
This email from eh.asgari@gmail.com originates from outside Imperial. Do not click on links and attachments unless you recognise the sender. If you trust the sender, add them to your safe senders list to disable email stamping for this address.
Dear All,
I am trying to compare the performance of different expansion types.However, when I set TYPE="GLL_LAGRANGE_SEM", I get the following error:
=======================================================================
EquationType: UnsteadyNavierStokes
Session Name: MeshWith3PrismsLayers
Spatial Dim.: 3
Max SEM Exp. Order: 5
Num. Processes: 128
Expansion Dim.: 3
Projection Type: Continuous Galerkin
Advect. advancement: explicit
Diffuse. advancement: implicit
Time Step: 0.0005
No. of Steps: 1000000
Checkpoints (steps): 1000
Integration Type: IMEX
Splitting Scheme: Velocity correction (strong press. form)
=======================================================================
Initial Conditions:
- Field u: 1.0
- Field v: 0.0
- Field w: 0.0
- Field p: 0.0
renaming "MeshWith3PrismsLayers_0.chk" -> "MeshWith3PrismsLayers_0.bak0.chk"
Writing: "MeshWith3PrismsLayers_0.chk"
(0.186233s, HDF5)
[gra723:25064:0:25064] Caught signal 11 (Segmentation fault: address not mapped to object at address 0x3025)
Here is my setup:
<?xml version="1.0" encoding="utf-8" ?>
<NEKTAR>
<EXPANSIONS>
<E COMPOSITE="C[30011]" NUMMODES="5" TYPE="GLL_LAGRANGE_SEM" FIELDS="u,v,w,p" />
</EXPANSIONS>
<CONDITIONS>
<FUNCTION NAME="InitialConditions">
<E VAR="u" VALUE="1.0" />
<E VAR="v,w,p" VALUE="0.0" />
</FUNCTION>
<SOLVERINFO>
<I PROPERTY="SolverType" VALUE="VelocityCorrectionScheme"/>
<I PROPERTY="EqType" VALUE="UnsteadyNavierStokes" />
<I PROPERTY="Projection" VALUE="Continuous" />
<I PROPERTY="EvolutionOperator" VALUE="Nonlinear" />
<I PROPERTY="TimeIntegrationMethod" VALUE="IMEXOrder2" />
<I PROPERTY="GlobalSysSoln" VALUE="IterativeStaticCond" />
<I PROPERTY="Driver" VALUE="Standard" />
</SOLVERINFO>
<GLOBALSYSSOLNINFO>
<V VAR="u,v,w">
<I PROPERTY="GlobalSysSoln" VALUE="IterativeStaticCond" />
<I PROPERTY="Preconditioner" VALUE="LowEnergyBlock"/>
<I PROPERTY="IterativeSolverTolerance" VALUE="1e-8"/>
</V>
<V VAR="p">
<I PROPERTY="GlobalSysSoln" VALUE="IterativeStaticCond" />
<I PROPERTY="Preconditioner" VALUE="FullLinearSpaceWithLowEnergyBlock"/>
<I PROPERTY="IterativeSolverTolerance" VALUE="1e-7"/>
</V>
</GLOBALSYSSOLNINFO>
Everything works fine with TYPE="MODIFIED". Noteworthy, I tried TYPE="GLL_LAGRANGE_SEM" with the periodic pipe tutorial and it worked there, which is adding to my confusion!Could you kindly point out if something is wrong with my setup?
Kind regardssyavash
_______________________________________________ Nektar-users mailing list Nektar-users@imperial.ac.uk https://mailman.ic.ac.uk/mailman/listinfo/nektar-users