Dear Ding, In what way does your measurement differ from the literature. Is the difference substantial? Could you provide a plot of the output showing the differences? One challenge in this problem is the inconsistent boundary conditions at the ends of the top wall. The values used at the top left and top right corners depends on the order of the boundary conditions. You could therefore swap the order of the boundary regions/conditions in the XML file and see if that improves your solution? Cheers, Chris On 22/08/16 06:15, 丁老师 wrote:
Dear Nektar group: I am conducting numerical simulation for 2D lid driven cavity problem with Re=1000. Attachment please find my xml file. But i found the output results at monitor point is different from benchmark solution from open literature. I have changed the order from 20 to 40, the nothing changed. but the stream line pattern is the same with benchmark solution. what should i do further>
Regards Your Sincerely Ding
_______________________________________________ Nektar-users mailing list Nektar-users@imperial.ac.uk https://mailman.ic.ac.uk/mailman/listinfo/nektar-users
-- Chris Cantwell Imperial College London South Kensington Campus London SW7 2AZ Email: c.cantwell@imperial.ac.uk www.imperial.ac.uk/people/c.cantwell