Hi Saad,
Actually, I had the same problem but I may say the problem was solved by using FieldConvert in serial, otherwise by using IncNavierStokesSolver in parallel. I mean, one can obtain a single vtu (or plt) file, even if there are multiple chk (or fld) "files in folders" generated in parallel FieldConvert, by converting multiple files into a single output file by applying a "one-time-only" serial run.
However, it should be noted that this makes the process longer, but may help your problem. (e.g., I am working with more than 250 processors, producing big data, using this method to get results and it works.)
Regards,
Selman Baysal
R. A. in HydraulicsDept. of Civil Eng'gÇanakkale Onsekiz Mart University--ITU Civil Eng., BSc.ITU Coastal Sci. & Eng., MSc.GSM: +905436180777_______________________________________________Kimden: stanislaw.gepner@pw.edu.pl;Kime: nektar-users@imperial.ac.uk; - 11/06/22 - 05:49Konu: Re: [Nektar-users] Parallel FieldConvert output in one single vtu file ?
Ho Saad,
You could try to produce a .plt file (a binary Tecplot format), and if your PV support it read this in. The benefits of plt files is size, and that it is a single file. With the PV support for plt. It used to be, that you needed to compile PV to use it, but I think now it is in the binaries (at least on Ubuntu).
Cheers,
Stan
On 11.06.2022 11:24, Debbahi Saad wrote:
This email from saad.debbahi@gmail.com originates from outside Imperial. Do not click on links and attachments unless you recognise the sender. If you trust the sender, add them to your safe senders list to disable email stamping for this address.
Hi All,
I'm on Nektar version 5.1.0, ending with datasets composed of moderate size files in numbers reaching few hundreds using the Incompresible Navier-Stokes Solver,
I just want to use parallel FieldConvert to speed up the conversion process (which actually provide a real gain in speed) and produce a single vtu file, since opening *.pvtu format datasets gave an error in paraview-openmpi-5.9.1 ,The command I'm using for parallel FieldConvert looks like this:
mpirun -n 16 FieldConvert -m mapping model.xml model_i.chk model_i.vtu
this creates n .vtu files under a .pvtu header, which as I reported earlier gives rise to this error:ERROR: In /builddir/build/BUILD/ParaView-v5.9.1/VTK/IO/XML/vtkXMLPDataReader.cxx, line 315
vtkXMLPUnstructuredGridReader (0x55ffb1431450): File for piece 0 cannot be read.
Is it possible to produce one single .vtu file out of parallel FieldConvert ?
Thanks in advance, any help on this or workaround will be really appreciated,
Kind regards,
Saad
_______________________________________________ Nektar-users mailing list Nektar-users@imperial.ac.uk https://mailman.ic.ac.uk/mailman/listinfo/nektar-users--
Best regards,
Stanisław Gepner, Ph.D.
Faculty of Power and Aeronautical Engineering
Nowowiejska 21/25 Str.
00-665 Warsaw, Poland
phone +48 (22) 234 51 70
[image : ]
Nektar-users mailing list
Nektar-users@imperial.ac.uk
https://mailman.ic.ac.uk/mailman/listinfo/nektar-users