Hi Andrew,

In our case we use second order and this is what we prescribe in the session file:

        <SOLVERINFO>


            [...]


            <I PROPERTY="TimeIntegrationMethod" VALUE="DIRKOrder2"              />


            [...]


        </SOLVERINFO>


Cheers,

Margarida

On Fri, 27 Jan 2023 at 11:03, Andrew Barnes <A.Barnes2@lboro.ac.uk> wrote:

This email from A.Barnes2@lboro.ac.uk originates from outside Imperial. Do not click on links and attachments unless you recognise the sender. If you trust the sender, add them to your safe senders list to disable email stamping for this address.

 

Hello everyone,

I'm trying to use the DIRK Time Integration methods in the CompressibleFlowSolver but keep getting an error when trying to specify the order and variant.

If I specify only <I PROPERTY="TimeIntegrationMethod" VALUE="DIRK"        /> in SolverInfo it will work perfectly, however I am unsure which order this is using. When I try to define VALUE="DIRKOrder3"  or  in a separate TIMEINTEGRATIONSCHEME section as below instead, it will produce the error bad_function_call.

<TIMEINTEGRATIONSCHEME> 
  <METHOD> DIRK </METHOD> 
  <ORDER> 3 </ORDER> 
</TIMEINTEGRATIONSCHEME>

Could anyone clarify:
  1. Which order is used for the default "DIRK" model?
  2. What would be the correct way to specify the order of DIRK model?
Thank you in advance,
Andrew
_______________________________________________
Nektar-users mailing list
Nektar-users@imperial.ac.uk
https://mailman.ic.ac.uk/mailman/listinfo/nektar-users


--
Margarida Moragues Ginard
MSCA-IF Researcher
BCAM - Basque Center for Applied Mathematics
Alameda de Mazarredo, 14
E-48009 Bilbao, Basque Country - Spain
Tel. +34 946 567 842

(matematika mugaz bestalde)