<FILTER TYPE="ReynoldsStresses">
<PARAM NAME="OutputFile">AverageField</PARAM>
<PARAM NAME="RestartFile">MyRestartAvg.fld</PARAM>
<PARAM NAME="OutputFrequency">100</PARAM>
<PARAM NAME="SampleFrequency"> 10 </PARAM>
</FILTER>
<FILTER TYPE="HistoryPoints">
<PARAM NAME="OutputFile">TimeValues</PARAM>
<PARAM NAME="OutputFrequency">10</PARAM>
<PARAM NAME="Points">
1 0 10
2 0 10
3 0 10
4 0 10
5 0 10
6 0 10
7 0 10
</PARAM>
</FILTER>
<FILTERS>
</NEKTAR>
Cheers
Bofu
------------------ 原始邮件 ------------------
发件人: "Amitvikram Dutta"<amitvdutta23@gmail.com>;
发送时间: 2018年5月18日(星期五) 晚上9:05
收件人: "nektar-users"<nektar-users@imperial.ac.uk>;
主题: [Nektar-users] History points and reynoldstress files
Hi all,
I'm trying to use the Reynolds Stresses time - averaged filter and the History Points filter on my current case. The appropriate section of the .xml file looks like this
<FILTER TYPE="ReynoldsStresses">
<PARAM NAME="OutputFile">AverageField</PARAM>
<PARAM NAME="RestartFile">MyRestartAvg.fld</PARAM>
<PARAM NAME="OutputFrequency">100</PARAM>
<PARAM NAME="SampleFrequency"> 10 </PARAM>
</FILTER>
<FILTER TYPE="HistoryPoints">
<PARAM NAME="OutputFile">TimeValues</PARAM>
<PARAM NAME="OutputFrequency">10</PARAM>
<PARAM NAME="Points">
1 0 10
2 0 10
3 0 10
4 0 10
5 0 10
6 0 10
7 0 10
</PARAM>
</FILTER>
The simulation runs fine over 10000 time steps. However, no .his files or .fld files for reynolds stresses are generated. I'm in a bit of a quandry as to how to resolve this issue. PFA the full .xml file as well.
--
Amitvikram Dutta
Graduate Research Assistant
Fluid Mechanics Research Lab
Multi-Physics Interaction Lab
University of Waterloo