Thanks Chi Hin

Are you implying that WSS module would automatically utilize the time-averaged velocity in the fld file?
Inside the fld file I have Reynolds stress as well. So I was unsure how WSS would recognize the components of the time-averaged velocity field.

Kind regards
syavash

On Tue, Jun 6, 2023, 15:12 Chan, Chi Hin <chi.chan19@imperial.ac.uk> wrote:
Hi Syavash

You could use FieldConvert’s WSS module. For instance, if the wall boundary ID is 0, 

FieldConvert -m wss:bnd=0 <mesh.xml> <session.xml> <time-averaged.fld> <time-averaged-wss.fld>
 
The output fld will either be a 1D/2D field of wss values on the boundary ID for a 2D/3D flow field. 

If you wish to compute mean of the wss, you can use FieldConvert -m mean with the appropriate 1D/2D mesh file of the boundary obtained using Nekmesh -m extract. Hope this helps

Cheers
Chi Hin

From: nektar-users-bounces@imperial.ac.uk <nektar-users-bounces@imperial.ac.uk> on behalf of Ehsan Asgari <eh.asgari@gmail.com>
Sent: Tuesday, June 6, 2023 8:07:43 AM
To: nektar-users <nektar-users@imperial.ac.uk>
Subject: [Nektar-users] Calculating time-averaged wall shear stress
 

This email from eh.asgari@gmail.com originates from outside Imperial. Do not click on links and attachments unless you recognise the sender. If you trust the sender, add them to your safe senders list to disable email stamping for this address.

 

Dear All,

I have a time-averaged field, say "time-average.fld". How should I proceed to calculate time-averaged wall shear stress? I was wondering if I need to use "wss" first.

Kind regards
syavash