Hi Spencer, all,

Yes, this is correct.

Cheers,
Gian

Gianmarco Mengaldo
Website: gmengaldo.com



On Dec 17, 2018, at 8:03 AM, Sherwin, Spencer J <s.sherwin@imperial.ac.uk> wrote:

HI,

I suspect that the value are not used internally in this solver and filled during each time step. It may be necessary to have the key word VALUE defined however for the input to work correctly.

I am cc’ing Gian and Giacomo to confirm whether this is correct.

Cheers,
Spencer.


On 17 Dec 2018, at 02:17, 中华腾飞 <592835068@qq.com> wrote:

Hi all!
Can you give me an specific example in using 'PressureOutflow' and 'WallAdiabatic' boundary conditions? On the website i don't know why the values are set to zeros...
<38F9F60C@098CBD02.4F07175C.jpg>
_______________________________________________
Nektar-users mailing list
Nektar-users@imperial.ac.uk
https://mailman.ic.ac.uk/mailman/listinfo/nektar-users

Spencer Sherwin FREng, FRAeS
Head, Aerodynamics,
Director of Research Computing Service,
Professor of Computational Fluid Mechanics,
Department of Aeronautics,
s.sherwin@imperial.ac.uk                                   South Kensington Campus,
Phone: +44 (0)20 7594 5052                              Imperial College London,
Fax:   +44 (0)20 7594 1974                               London, SW7 2AZ,  UK
http://www.imperial.ac.uk/people/s.sherwin/